3222 N - electric - DIN
Globe valve
VALVE STYLE
Globe valve
USAGE
- Low-pressure service
- Throttling service
VERSION
DIN
MEDIUM TEMPERATURE
5
to 120 °C /
41
to
248 °F
SUPPLY
Electric
VALVE SIZE
DN 15
PRESSURE RATING
PN 16
LINING
without
Special features
- Consisting of single-seated globe valve and actuator
- Particularly suitable for local heat supply and large heating networks
Accessories
- Type 2 NI Strainer
Options
- Intermediate insulating piece
- Threaded ends
- Welding ends
- Soldering ends
3222 N - electric - DIN can be combinated with the following actuations:
Special features:
- Linear actuator for force-locking connection to valves
- Optionally three-step version or with digital positioner
- Motor switched off by torque-dependent limit contacts
- Mechanical override
- Travel indicator
- With synchronous motor and maintenance- free gear
- Initialization by pressing a button
- Direction of action reversed by slide switch
- Momentary travel calculated from transit time
- Operating status and errors indicated by LEDs
- Adjustable stroking speed
- Blockage detection and removal
- Blocking protection
- Adjustable input and output signal ranges
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
Special features:
- Linear actuator with integrated digital controller
- Force-locking connection to valves
- Motor switched off by torque-dependent limit contacts
- DHW heating control in instantaneous heating systems used in small to medium-sized buildings connected to a district heating or local heat supply network
- Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
- Binary input to switch between set points
- Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
- Reversible direction of action
- Limit value monitoring
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
- Diagnosefunktion und Online-Verbindung zur Beobachtung über die Software TROVIS-VIEW
- Operating status and errors indicated by LEDs
- Travel indicator
- Manual override
Special features:
- Linear actuator with integrated digital controller
- Force-locking connection to valves
- Motor switched off by torque-dependent limit contacts
- Control of small to medium-sized buildings
- Outdoor-temperature-compensated control, fixed set point control, or fixed set point control with room temperature sensors
- Return flow temperature limitation
- Frost monitoring and automatic initiation of protective action
- Automatic anti-blocking function prevents circulating pumps from seizing up
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
- Diagnosefunktion und Online-Verbindung zur Beobachtung über die Software TROVIS-VIEW
- Operating status and errors indicated by LEDs
- Travel indicator
- Manual override
Information
Support
DXF file from data sheet
- T 5867 [ZIP]
Certificates
Only up-to-date documents are shown in the product selector. Check the documentation site for a list of all documents available.